EFKA AB220A5111
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
297 M11 Functions of signal M11 5 0 0 A
0 = Function according to setting of parameter 290.
1 = Signal M11 is switched on whenever the light
barrier is uncovered (pa. 131 = 1) or covered
(pa. 131 = 0)
2 = Signal M11 is switched on whenever the light
barrier is covered (pa. 131 = 1) or uncovered
(pa. 131 = 0)
3 = Signal M11 is switched on only after light barrier
uncovered and/or covered until seam end
4 = Signal M11 is switched on as with setting 3.
Signal M5 (machine running), however, is
switched off while signal M11 is issued.
When signal M11 is issued, signal M6 (machine
at standstill) is also immediately issued.
5 = Signal M11 is switched on from “light barrier
sensing“, “pedal in pos. –2“ or “‘hemmer foot
signal’ key off“ onwards.
298 nSo Backtack synchronization On/Off 1 0 0 A
299 nrS Backtack synchronization speed RPM 3000 **) 200 400 A
300 AA1 Selectable power transistors for signal A1 12 0 0 A
0 =No function
1 =Signal on output M1
2 =Signal on output M2
3 =Signal on output M3
4 =Signal on output M4
5 =Signal on output M5
6 =Signal on output M6
7 =Signal on output M7
8 =Signal on output M8
9 =Signal on output M9
10 =Signal on output M10
11 =Signal on output M11
12 =Signal on output VR
301 So1 Issue signal A1 3 0 0 A
0 =Signal until seam end (according to setting of
parameter 320)
1 =Signal over time
2 =Signal until seam end and drive stops
3 =Signal during stitch counting (according to setting
of parameter 309)
302 tr1 Starting point for signal A1 3 0 0 A
0 =Start at the beginning of the seam
1 =Start of the signal triggered by light barrier sensing
2 =Start of the signal when the drive stops at the seam
end
3 =Start from light barrier covered onwards at the
beginning of the seam
303 do1 Delay of signal A1 2 0 1 A
0 =No delay until signal On
1 =Delay over time until signal On
2 =Delay over stitches until signal On
304 dt1 Delay time until signal A1 On ms 2550 **) 0 0 A
305 St1 ON period of signal A1 ms 2550 **) 0 0 A
306 nA1 Speed mode when signal A1 is On 2 0 0 A
0 =Pedal controlled speed
1 =Limited speed n9
2 =Limited speed n11
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.