Duerkopp Adler HP Series Additional guide Instrukcja Obsługi Strona 68

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 84
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 67
EFKA AB220A5111
68
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
237 tkS Switch-off delay for chain suction at the ms 2550 **) 0 0 A
seam end, if parameter 022 = 2.
238 EnP Software debouncing for all inputs: 1 0 1 A
0 = No debouncing
1 = With debouncing
239 FEL Selection of the input function on socket B18/5 47 0 0 A
0 = Light barrier function, if 009 = 1
All other functions as with parameter 240.
240 in1 Selection of the input functions on socket ST2/7 47 0 0 *) A
for input 1
0 = No function
1 = Needle up/down
2 = Needle up
3 = Single stitch (basting stitch)
4 = Full stitch
5 = Needle to position 2
6 = Machine run blockage effective with open
contact
7 = Machine run blockage effective with closed
contact
8 = Machine run blockage unpositioned effective
with open contact
9 = Machine run blockage unpositioned effective
with closed contact
10 = Automatic speed n12 without pedal
11 = Limited speed n12 pedal controlled
(see parameter 266)
12 = Sewing foot lifting with pedal in position 0
(neutral)
13 = High lift for walking foot with speed limitation n10
(operational mode not stored)
14 = High lift for walking foot (flip-flop 1) with speed
limitation n10
15 = Tape cutter / fast scissors: function only in
chainstitch and overlock mode
16 = Intermediate backtack / intermediate stitch
condensing
17 = Stitch regulator suppression / recall
18 = Unlocking the chain: can be activated by
keystroke, but will be executed only at the
seam end
19 = Reset bobbin thread monitor if parameter
030 = >0
20 = Handwheel running in the direction of rotation
according to the setting of parameter 161
21 = Handwheel running in the opposite direction of
rotation according to the setting of parameter
161
22 = Speed limitation n11 (flip-flop 2). Output
ST2/29 is enabled according to setting of
parameter 186
23 = No function
24 = No function
25 = Speed limitation with ext. potentiometer
On/Off (see parameter 126)
26 = Manual stacker
27 = Unlocking the chain, function is performed
upon pressing the key
28 = External light barrier (according to the
setting of parameter 131)
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.