EFKA AB220A5111
36
Mode 4, 5, 6 or 7 (function “unlocking the chain” with light barrier)
Mark Function Parameter Control V810 V820
Mode 5 290 = 5
drE Direction of motor rotation Clockwise 161 = 0
Frd Reverse motor rotation 182 = 1
Basic position 2 On S5 key 4 key 7 key
End stitch condensing and thread trimmer *) On
Light barrier 009 = ON
Unlock the chain automatically with light barrier 190 = 2
in7 Machine run blockage effective with open contact 246 = 6
in8 Automatic speed n12 without pedal 247 = 10
in.. Assign the function “unlocking the chain” to an output 2..
n1 Positioning speed 110
n2 Maximum speed 111
n5 Speed after light barrier sensing 114
t3 Start delay from lifted sewing foot 202
t4 Full power of sewing foot lifting 203
t5 Pulsing of sewing foot lifting 204
LS Light barrier compensating stitches 004
ird Number of reversing increments 180
drd Switch-on delay of reverse motor rotation 181
tGn Speed gate damping period 222
dGF Speed gate 2 224 = 1
kdF Switch-on delay of sewing foot lifting 288
*) When unlocking the chain, the functions “stitch condensing” and “thread trimmer” are suppressed!
ST2/35
ST2/34
ST2/32
(ML)
(MST)
30ST2/
ENTK
LS
STV
M5
M6
FL
t3
ST2/20
ST2/21
n
POS.2
POS.1
-
+
-2
-1
0
1
1/2
LS
n2
60 34 5
n5
7
t4 t5
n1
drd ird
n1
0256/ENTK-1
Przeglądanie stron 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 83 84

Komentarze do niniejszej Instrukcji

Brak uwag