EFKA AB220A5111
52
Mode 20 (lockstitch Juki LU1510-7)
Mark Function Parameter Control V810 V820
Mode 20 290 = 20
Double start backtack On S2 key 1 key 1 key
Double end backtack On S3 key 2 key 4 key
Reverse motor rotation 182 = 1
in3 Speed limitation bit 0 242 = 31
in4 Speed limitation bit 1 243 = 32
n2 Maximum speed 111
n3 Start backtack speed 112
n4 End backtack speed 113
n7 Trimming speed 116
n9 Automatic speed 122
n10 Automatic speed 117
n11 Automatic speed 123
t1 Delay until speed release after start backtack 200
t3 Start delay from lifted sewing foot 202
t7 Sewing foot switch-on delay after thread wiper 206
ird Number of reversing increments 180
drd Switch-on delay of reverse motor rotation 181
iFA Activation angle of the thread trimmer 250
FSA Thread tension release ON period 251
FSE Thread tension release delay depending on angle 252
c2 Start backtack stitches forward 000
c1 Start backtack stitches backward 001
c3 End backtack stitches backward 002
c4 End backtack stitches forward 003
0
ST2/6
ST2/8
ST2/37
ST2/28
ST2/34
ST2/35
ST2/21
M2
in4
in3
M1
VR
FL
(FSPL)
(BIT1)
(BIT0)
(FA)
t3
ST2/20
POS.1
POS.2
-
-2
n
/
0
1
21
+
-1
c2 t1c1
1123 23
n3 n2 n11 n9
c3
FSE
iFA
c4
1
n2n10
0 2 21
n7n4
3
0256/MODE-20
FSA
t7
drd ird