Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit max min Preset Ind.
296 M08 Functions of signal M8 5 0 0 *) A/A/A/A
0 = Signal M8 Off
1 = Signal hemmer foot On at the start of the seam
with pedal in pos. -1 or –2 and in the seam with
machine running
2 = Signal hemmer foot On at the start of the seam
with pedal in pos. -1 or –2 and remains active in
the seam
3 = Signal M8 as center cutter
4 = Signal M8 with needle up / down
5 = Signal M8 alternating with M3 with “fast scissors”
on overlock machines in mode 16,
if parameter 232=1 has been selected
297 M11 Functions of signal M11 6 0 0 F/F/F/E
0 = Function according to setting of parameter 290.
1 = Signal M11 is switched on whenever the light
barrier is uncovered (pa. 131 = 1) or covered
(pa. 131 = 0)
2 = Signal M11 is switched on whenever the light
barrier is covered (pa. 131 = 1) or uncovered
(pa. 131 = 0)
3 = Signal M11 is switched on only after light barrier
uncovered and/or covered until seam end
4 = Signal M11 is switched on as with setting 3.
Signal M5 (machine running), however, is
switched off while signal M11 is issued.
When signal M11 is issued, signal M6 (machine
at standstill) is also immediately issued.
5 = Signal M11 is switched on from “light barrier
sensing“, “pedal in pos. –2“ or “‘hemmer foot
signal’ key off“ onwards.
6 = Signal M11 is On, when the key on input in 2 is
open.
Signal M11 is switched off after the section
set by means of parameter 007 has been executed,
when the key on input in2 is closed. At drive
standstill, signal M11 is switched off immediately.
298 nSo Backtack synchronization On/Off 1 0 0 A/A/A/A
299 nrS Backtack synchronization speed RPM 3000 **) 200 400 A/A/A/A
300 AA1 Selectable power transistors for signal A1 12 0 0 A/A/A/A
0 = No function
1 = Signal on output M1
2 = Signal on output M2
3 = Signal on output M3
4 = Signal on output M4
5 = Signal on output M5
6 = Signal on output M6
7 = Signal on output M7
8 = Signal on output M8
9 = Signal on output M9
10 = Signal on output M10
11 = Signal on output M11
12 = Signal on output VR
301 So1 Issue signal A1 4 0 0 F/F/F/E
0 = Signal until seam end (according to setting of
parameter 320)
1 = Signal over time
2 = Signal until seam end and drive stops
3 = Signal during stitch counting (according to setting
of parameter 309)
4 = Signal A1 as puller function
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.