EFKA AB220A/320A FP220A/320A
44
Mode 7 (overlock) parameter 232 = 0 (tape cutter) / parameter 018 = 1 (seam end without stop)
kt3
LS
ST2/30
ST2/32
M6
M5
(MST)
(ML)
t3
M4
M2
ST2/28
ST2/36
M3
ST2/37
ST2/27
M1
POS.2
ST2/21
ST2/35
ST2/34
FL
KS
(AH)
(FSPL)
ST2/20
POS.1
0
-2
-1
+
n
1
/2
-
1
kt3c3
c1
c4
6
n3
0 1 2 3 4 5
n4
2 3 4 65 71
n2
0256/ MODE- 7b
n7
c3 kt3
c1
0 31 2
n3
54 6
n2 n1
kt1kd1
kt2kd2
kdF t4 t5
Mark Function Parameter Control V810 V820
FAm Mode 7 290 = 7
Counts c1, c2, c3 and c4 On S2/3 key 1/2 key 1/4 key
LS Light barrier compensating stitches 004 = 0
LS Light barrier 009 = 1
UoS Sequence “overlock mode at the seam end without stop” 018 = 1
-Pd Function “pedal in pos. –1/–2” activated in the seam 019 = 3
SPO Chain suction at the seam end until pedal in pos. 0 022 = 1
kSA Stitch counting at the start of the seam at fixed 143 = 1
speed n3
kSE Stitch counting at the seam end at fixed speed n4 144 = 1
USS Tape cutter function 232 = 0
n1 Positioning speed 110
n2 Maximum speed 111
n3 Speed for start counting 112
n7 Trimming speed 116
c1 Start counting for chain suction 001
c3 Start counting for tape cutter 002
c4 End counting for tape cutter 003
t3 Start delay from lifted sewing foot 202
kd1/kd2 Delay times of outputs M1/M2 280/282
kt1/kt2 ON periods of outputs M1/M2 281/283
kt3 ON period of tape cutter 285
kdF Switch-on delay of sewing foot lifting 288